  1. STP-154: 2021-06-29T03:20 – 09:20 (DOY 180) around TCM 
  2. STP-154: 2021-07-04T01:00 (DOY 185) – STP-155: 2021-07-05T11:30 (DOY 186) SA rotation, Thermogravimetric Analysis, and WOL 
    • 0100 Switch-on
    • 0130-0300 Test mode
    • 0300-0800 CMS-2 TGA
      • level ended up at was slightly lower than we went in on (75).
    • -> 80degC set-point, 1degC/minute controlled heating and cooling
    • 0800-1200 Test mode
    • 1200-1400 Test mode (SA_ROT from 0 to 30 degrees)
    • 1400-2025 CMS-1 TGA + Peltier
      • CMS had an initial set point that was able to cool, because the set point wasn’t perfect (can’t be, and depends on HIS power status)
      • There shouldn’t be much material collected there, but the level does look higher.
      • -> 80degC set-point, 1degC/minute controlled heating and cooling
    • -> End at -10degC, and stay in Peltier control for ~2 hours
    • -> Note: previous test was at -30degC (November 2020), but the set-point could not be maintained. 
    • Also, the S/C is ~10degC warmer now due to heater changes, so the set-point has been raised by 20degC for this attempt. 
    • 2025-2100 Peltier Off
    • 2100-0000 Test mode (monitoring thermal recovery)
    • 0000-0600 Test mode (WOL)
    • 0600-1130 Test mode (monitoring thermal recovery)
    • 1130 switch-off
    • Sunday 4th July (STP154):
    • Monday 5th July (STP155)
    • A eteter better exercise this time around, given what we learned first time around. THe The completion of the tempreatures temperature change went o almost exactly where it was expected. So we can run Peltier at –10 at  –10ºC without issues.
    • LTP05 should be a little colder

...